220-01

220-01

Expert CYPRES 2

Expert CYPRES 2
larger imageMove mouse over the image to magnify
Enquire

Expert CYPRES 2

The Modern All-round Unit.

The best evidence of the unique quality and reliability of the Expert CYPRES 2 is the fact that this AAD has become a indispensable part of any qualified skydiver around the world. The Expert CYPRES 2 guarantees you the potentially needed emergency operation in practically any possible scenario.

Make sure you see the famous red button when you make your choice for your next AAD.

 

Check out the CYPRES Trade-In offer here: web trade-in USD

 

Standard Settings:

Activation speed: approx. >78 mph (35 m/s)
Activation altitude: approx. 750 feet  (225 meters)

Technical Data:
 

Cable length of control unit: approx. 650 mm
Volume: approx. 139 cm³
Weight: approx. 188 grams
Length, width, height of the processing unit: approx. 85 x 43 x 32 mm
Length, width, height of the control unit: approx. 65 x 18 x 6,5 mm
Length, diameter of the release unit: approx. 43 x 8 mm

Cable length of the release unit              (including release unit):

approx. 500 mm
Storage temperature: +71° to -25° Celsius
Storage pressure: 200 to 1070 hPa ( 5.906 to 31.597 In.Hg)
Working temperaturer: +63° to -20° Celsius *
Maximum allowable humidity: up to 99,9 % rel. humidity
Waterproof: up to 24 hours down to a depth of 5 feet (1.5 meters)
Altitude adjustment limits: ±3000 feet or ±1000 m
Operating range below / above sea level: -1500 feet to +26,000 feet (-500 m to +8000 m)
Functioning period: 14 hours from switch-on
Power supply: lifetime warranty**
Maintenance: For units with DOM 12/15 and earlier the maintenance is mandatory to be performed 4 and 8 years after the original DOM.
For units made in 2016 the maintenance is recommended to be performed 4 and 8 years after original DOM.
For units with DOM 01/17 and later the maintenance is recommended to be performed 5 and 10 years after the original DOM.***
Warranty Period: see Airtec warranty policy
Service Life: DOM prior 01.01.2017: 12.5 years from date of manufacture
DOM later 01.01.2017: 15.5 years from date of manufacture

 

* These temperature limits do not mean the outside (ambient) temperatures but rather temperatures
inside the processing unit. Therefore, these limits won‘t have any meaning until the processing unit
itself has reached the temperatures in question. In actual fact, these limits will rarely be reached due
to the mandatory location of the CYPRES in the reserve container, and the insulating properties of
the processing unit pouch and parachute canopies.

** If required maintenance has been performed.

***Anticipated, according to the present knowledge base.

 

Links:Do you require a CYPRES for high speed landings? Speed CYPRES 2

 

You can download the updated CYPRES2 Users Guide here

You might also be interested in ...